研究目的
To visualize and quantify the three-dimensional (3D) spatial relationships of the structures of the aqueous outflow system (AOS) within intact enucleated mouse eyes using spectral two-photon microscopy (TPM) techniques.
研究成果
Spectral TPM enables high-resolution 3D reconstruction and quantification of the AOS in mouse eyes, revealing detailed spatial relationships of structures like SC, CC, and AV. This technique provides a foundation for future in vivo studies on glaucoma progression and therapeutic evaluations, offering potential for clinical diagnosis and treatment of primary open-angle glaucoma.
研究不足
The study was conducted on enucleated mouse eyes, limiting direct application to in vivo conditions. The axial resolution was constrained by the diffraction limit, and step size in imaging may have affected 3D model smoothness. Smaller channels (<10 μm) were excluded from analysis, potentially overlooking contributions from minor outflow pathways. The use of fixed excitation wavelengths and specific dyes may not capture all dynamic aspects.
1:Experimental Design and Method Selection:
The study used spectral two-photon microscopy (TPM), including two-photon autofluorescence (TPAF) and second-harmonic generation (SHG), to image the AOS in intact mouse eyes. The design involved using long infrared excitation wavelengths (930 nm) to reduce scattering and background, with image stacks collected for 3D rendering and segmentation. Anatomical references were established using perfusion techniques with fluorescent dyes.
2:Sample Selection and Data Sources:
Experiments were performed on eyes from adult C57BL/6 mice (age 12–20 weeks) of either sex, enucleated immediately after euthanasia. Some experiments involved cardiac perfusion with FITC-dextran or trans-corneal perfusion with fluorescent beads.
3:List of Experimental Equipment and Materials:
Equipment included a Zeiss LSM 780 inverted confocal microscope, a Spectra-Physics Ti:Sapphire laser, a 34X/1.2NA water-immersion objective, a QUASAR detector, a Harvard Apparatus syringe pump, a Hamilton micro-syringe, and custom-built eye-holders. Materials included PBS, FITC-labeled dextran, fluorescent polystyrene beads, and Davidson's Fixative.
4:2NA water-immersion objective, a QUASAR detector, a Harvard Apparatus syringe pump, a Hamilton micro-syringe, and custom-built eye-holders. Materials included PBS, FITC-labeled dextran, fluorescent polystyrene beads, and Davidson's Fixative. Experimental Procedures and Operational Workflow:
4. Experimental Procedures and Operational Workflow: Eyes were placed on a custom holder, perfused if applicable, and imaged with TPM. Laser power was adjusted for depth compensation. Image stacks were acquired with specific parameters (e.g., pixel dwell time 1.54 μs). Post-processing involved segmentation and 3D rendering using software like ImageJ, Seg3D, and FluoRender.
5:54 μs). Post-processing involved segmentation and 3D rendering using software like ImageJ, Seg3D, and FluoRender. Data Analysis Methods:
5. Data Analysis Methods: Image analysis included brightness/contrast adjustments, segmentation based on intensity thresholds, and quantitative measurements of AOS structures using software tools. Statistical analysis involved calculating means and standard deviations from multiple measurements.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
LSM 780
LSM 780
Carl Zeiss AG
Used as an adapted laser scanning inverted confocal microscope for two-photon microscopy imaging.
ZEISS LSM 990 Spectral Multiplex
立即获取同款设备 -
Water-immersion objective
34X/1.2NA
Carl Zeiss AG
Used for imaging with high numerical aperture to achieve subcellular resolution.
暂无现货
预约到货通知
-
QUASAR detector
QUASAR
Carl Zeiss AG
Spectral detector for capturing fluorescent signals with 32 channels.
暂无现货
预约到货通知
-
Ti:Sapphire laser
Not specified
Spectra-Physics
Provided the excitation beam at 930 nm for two-photon microscopy.
暂无现货
预约到货通知
-
Syringe pump
Not specified
Harvard Apparatus
Programmable motorized syringe pump used for perfusion experiments.
暂无现货
预约到货通知
-
Micro-syringe
10-μL
Hamilton
Used for precise perfusion of fluids into the eye.
暂无现货
预约到货通知
-
Glass micro-needle
KwikFil
WPI
Needle made from borosilicate glass tubing for corneal perfusion.
暂无现货
预约到货通知
-
Pipette puller
Not specified
Zeitz Instruments GmbH
Used to prepare the tips of glass micro-needles.
暂无现货
预约到货通知
-
Microscope
Eclipse 80i
Nikon
Used for bright-field imaging of histologic sections.
暂无现货
预约到货通知
-
Camera
D5-Fi1
Nikon
Color camera attached to the microscope for imaging.
暂无现货
预约到货通知
-
Objective
20X CFI Plan Fluor
Nikon
Used for histologic imaging.
暂无现货
预约到货通知
-
登录查看剩余9件设备及参数对照表
查看全部