- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Photoemission and thermoluminescence characteristics of Dy3+-doped zinc sodium bismuth borate glasses
摘要: The present study reports preparation and characterization of Dy3+-doped PbO free alkali-heavy-metal-borate glasses for luminescent applications. The amorphous nature of the glasses and the presence of various structural groups like BiO6, BO3 and BO4 were confirmed through XRD and FTIR measurements. The Oscillator strength of Dy3+ absorption transitions as well as the bond formed with the O2- ion in the glass network were determined using the absorption spectra. Radiative parameters extracted from Judd-Ofelt theory proved the degree of suitability of prepared glasses for lasing applications. The photoluminescence spectra exhibited the emission characteristics of Dy3+ ions and used to calculate the branching ratio, stimulated emission cross-section and radiative lifetime. Metastable lifetimes of Dy3+ ions were obtained through exponential fitting of respective decay profiles. The luminescence quenching phenomena was reasoned using Inokuti-Hirayama (I-H) model. The optical gain and quantum efficiency values clearly suggested Dy3+ doping at 0.3 mol% was optimum for 587 nm lasing action. Further, CIE chromaticity plot indicated the possible applications in solid state lighting devices. The thermoluminescence glow curves of 0.3 mol% Dy3+-doped glasses were considered for gamma irradiation and kinetic parameters of the same were evaluated using Computerized Glow Curve Deconvolution (CGCD) technique.
关键词: luminescence,kinetic order,Rare earth,Judd-Ofelt parameter,lifetime
更新于2025-09-23 15:23:52
-
Adsorption and photodegradation efficiency of TiO2/Fe2O3/PAC and TiO2/Fe2O3/zeolite nanophotocatalysts for the removal of cyanide
摘要: The synthesized TiO2/Fe2O3 nanostructures supported on powder activated carbon (PAC) and zeolite at different mole ratios of Fe3+/TiO2 were characterized by XRD, XRF, FESEM, EDX, TEM, FTIR, BET and, PL analyses and their cyanide photodegradation mechanism was thoroughly discussed. The results confirmed not only TiO2/Fe2O3/PAC had higher photocatalytic and adsorption capability but also better structural stability and reusability for cyanide removal than TiO2/Fe2O3/zeolite. The first order kinetics model indicated that the photodegradation rate using TiO2/Fe2O3/PAC was 1.3 times higher than that of TiO2/Fe2O3/zeolite. The response surface methodology (RSM) assessment showed that pH, irradiation time and initial cyanide concentration using UV/H2O2/TiO2/Fe2O3/zeolite system had more effects on the degradation respectively; whereas the effectiveness of UV/H2O2/TiO2/Fe2O3/PAC process was highly influenced by initial cyanide concentration than the other two parameters. High R2 and well-fitted residual plots approved the accuracy of the models in predicting the cyanide degradation efficiency using both the photocatalysts.
关键词: and adsorption comparison,Cyanide,Response surface methodology (RSM),TiO2/Fe2O3/zeolite and TiO2/Fe2O3/PAC photocatalysts,Photodegradation,Kinetic
更新于2025-09-23 15:23:52
-
Photo-isomerization of azobenzene containing surfactants induced by near-infrared light using upconversion nanoparticles (UCNPs) as mediator
摘要: Here we report on photo-isomerization of azobenzene containing surfactants induced during irradiation with near-infrared (NIR) light in the presence of upconversion nanoparticles (UCNPs) acting as mediator. The surfactant molecule consists of charged head group and hydrophobic tail with azobenzene group incorporated in alkyl chain. The azobenzene group can be reversible photo-isomerized between two states: trans- and cis- by irradiation with light of appropriate wavelength. The trans-cis photo-isomerization is induced by UV light, while cis-trans isomerization proceeds either thermally in dark, or can be accelerated by exposing to illumination with longer wavelength typically in blue/green range. We present the application of lanthanide doped upconversion nanoparticles (UCNPs) to successfully switch azobenzene containing surfactants from cis to trans conformation in bulk solution using NIR light. Using Tm3+ or Er3+ as activator ions, the UCNPs provide emission in the spectral range of 450 nm < λem < 480 nm (for Tm3+, three and four photon induced emission) or 525 nm < λem < 545 nm (for Er3+, two photon induced emission), respectively. Especially for UCNPs containing Tm3+ a good overlap of the emission with the absorption bands of the azobenzene is present. Under illumination of the surfactant solution with NIR light (λex= 976 nm) in the presence of the Tm3+-doped UCNPs, the relaxation time of cis-trans photo-isomerization was increased by almost 13-times compared to thermal relaxation. The influence of thermal heating due to the irradiation using NIR light was shown to be minor for solvents not absorbing in NIR spectral range (e.g., CHCl3) in contrast to water, which shows a distinct absorption in the NIR.
关键词: azobenzene containing surfactants,kinetic of cis-trans isomerization,up-conversion particles
更新于2025-09-23 15:23:52
-
New Assay Method Based on Raman Spectroscopy for Enzymes Reacting with Gaseous Substrates
摘要: Enzyme activity is typically assayed by quantitatively measuring the initial and final concentrations of the substrates and/or products over a defined time period. For enzymatic reactions involving gaseous substrates, the substrate concentrations can be estimated either directly by gas chromatography or mass spectrometry, or indirectly by absorption spectroscopy, if the catalytic reactions involve electron transfer with electron mediators that exhibit redox-dependent spectral changes. We have developed a new assay system for measuring the time course of enzymatic reactions involving gaseous substrates based on Raman spectroscopy. This system permits continuous monitoring of the gas composition in the reaction cuvette in a non-invasive manner over a prolonged time period. We have applied this system to the kinetic study of the [NiFe] hydrogenase from Desulfovibrio vulgaris Miyazaki F. This enzyme physiologically catalyzes the reversible oxidation of H2 and also possesses the non-physiological functions of H/D exchange and nuclear spin isomer conversion reactions. The proposed system has the additional advantage of enabling us to measure all of the hydrogenase-mediated reactions simultaneously. Using the proposed system, we confirmed that H2 (the fully exchanged product) is concomitantly produced alongside HD by the H/D exchange reaction in the D2/H2O system. Based on a kinetic model, the ratio of the rate constants of the H/D exchange reaction (k) at the active site and product release rate (kout) was estimated to be 1.9±0.2. The proposed assay method based on Raman spectroscopy can be applied to the investigation of other enzymes involving gaseous substrates.
关键词: kinetic experiment,H/D exchange reaction,quantitative analysis of gaseous substrates,Raman spectroscopy,non-invasive measurement,[NiFe] hydrogenase
更新于2025-09-23 15:23:52
-
Dynamics of interatomic Coulombic decay in neon dimers by XUV-pump–XUV-probe spectroscopy
摘要: We apply the Monte Carlo wave-packet approach to study the interatomic Coulombic decay (ICD) dynamics of neon dimers after removing a 2s electron from one of the Ne atoms by one-photon absorption from an XUV pulse. This method reproduces well both the lifetime for the 2s inner-valence vacancy in Ne2+(2s?1) and the kinetic energy release (KER) spectra for the coincident Ne+ and Ne2+ fragments following triple ionization, i.e., two photoionizations and one ionization via ICD, of Ne2 measured in an XUV-pump–XUV-probe experiment [K. Schnorr et al., Phys. Rev. Lett. 111, 093402 (2013)]. Comparisons between the calculated and measured nuclear KER spectra give physical insights in the considered process. For example, an analysis of the ratios between the low- and high-energy peaks in the nuclear KER spectra for large delays provides an estimate of the photoionization cross sections for removing a 2p electron from the excited states in Ne2+(2s?1). Such comparisons also allow an estimate for the ICD rates for the 2s inner-valence vacancy in the single-site two-hole state in Ne2+(2s?12p?1). Finally, the influence of photon statistics of the free electron laser pulses on the nuclear KER spectra is considered.
关键词: neon dimers,interatomic Coulombic decay,kinetic energy release spectra,XUV-pump–XUV-probe spectroscopy,Monte Carlo wave-packet approach
更新于2025-09-23 15:23:52
-
The Comparison of the Photocatalytic Performance Shown by TiO <sub/>2</sub> and TiO <sub/>2</sub> /WO <sub/>3</sub> Composites— A Parametric and Kinetic Study
摘要: Kinetic and mechanistic related approaches for mostly titania were intensively studied in the literature. However, combined modelling and kinetic studies are few. Therefore, the present work focuses on modelling the dependence of the degradation kinetics of two model compounds (salicylic acid—SA and methyl orange—MO) on Evonik Aeroxide P25, hydrothermally prepared hierarchical TiO2 and P25/WO3 nanostars, obtained also by hydrothermal crystallization. The obtained individual semiconductors and the composites were characterized using XRD, DRS, SEM, while the photocatalytic degradation of the model pollutants were carried out varying the catalyst load, the initial pollutant concentration and incident light intensity. It was found that the degradation kinetics were independent from the hierarchical nature of the material, while significant dependencies of the degradation efficiency was found from the previously mentioned investigation parameters. All these parametric interdependences were successfully studied and a kinetic model was proposed for both bare TiO2 and TiO2/WO3 composite systems.
关键词: Degradation,Salicylic Acid,Methyl Orange,Kinetic Modelling,Composite Materials
更新于2025-09-23 15:22:29
-
A unified framework for plasma data modelling in dynamic Positron Emission Tomography studies
摘要: Objective: Full quantification of dynamic PET data requires the knowledge of tracer concentration in the arterial plasma. However, its accurate measurement is challenging due to the presence of radiolabeled metabolites and measurement noise. Mathematical models are fitted to the plasma data for both radiometabolite correction and data denoising. However, the models used are generally not physiologically informed and not consistently applied across studies even when quantifying the kinetics of the same radiotracer, introducing methodological variability affecting the results interpretation. The aim of this study was to develop and validate a unified framework for the arterial data modelling to achieve an accurate and fully-automated description of the plasma tracer kinetics. Methods: The proposed pipeline employs basis pursuit techniques for estimating both radiometabolites and parent concentration models from the raw plasma measurements, allowing the resulting algorithm to be both robust and flexible to the different quality of data available. The pipeline was tested on four PET tracers ([11C]PBR28, [11C]MePPEP, [11C]WAY-100635 and [11C]PIB) with continuous and discrete blood sampling. Results: Compared to the standard procedure, the pipeline provided similar fit of the parent fraction but yielded a better description of the total plasma radioactivity, which in turn allowed a more accurate fit of the tissue PET data. Conclusion: The new method showed superior fits compared to the standard pipeline, for both continuous and discrete arterial sampling protocol, yielding to better description of PET data. Significance: The proposed pipeline has the potential to standardize the blood data modeling in dynamic PET studies given its robustness, flexibility and easiness of use.
关键词: Kinetic modelling,Positron Emission Tomography,Input function,Receptor imaging
更新于2025-09-23 15:22:29
-
Hydrolysis kinetics of silane coupling agents studied by near-infrared spectroscopy plus partial least squares model
摘要: A method of Fourier transform near-infrared (FT-NIR) spectroscopy combined with partial least squares (PLS) model was successfully applied to investigate the hydrolysis kinetics of four kinds of silane coupling agents (phenyltriethoxysilane, vinyltriethoxysilane, 3-mercaptopropyltriethoxysilane, 3-chloropropyltriethoxysilane) in an acid-catalyzed EtOH system. The fast scanning speed and high sensitivity of the FT-NIR spectroscopy, and the powerful data processing ability of the PLS, enabled the method to quantitatively and accurately catch the fast changing H2O concentration during the hydrolysis processes without delay, realizing the study of the fast-paced hydrolysis reactions of the silane coupling agents. The results showed that electrophilic substitution occurred in the hydrolysis reactions, which followed second-order reactions and greatly depend on the catalyst concentration and reaction temperature. The hydrolysis rate constants, activation energy, and Arrhenius Frequency factors were gained. In conclusion, the FT-NIR PLS model is a powerful tool for hydrolysis kinetics researching of the silane coupling agents.
关键词: partial least squares,Hydrolysis kinetic,silane coupling agent,near infrared
更新于2025-09-23 15:22:29
-
Preparation and Luminescence Properties of Ba5Si8O21 Long Persistent Phosphors Doped with Rare-Earth Elements
摘要: The phosphors of formula Ba5Si8O21:Eu2+,Dy3+ were synthesized and studied in order to improve their properties. Their synthesis conditions were evaluated as a function of precursors, crucible composition, flux agents, dopants and temperatures. The samples were characterised by means of a systematic investigation through elemental, kinetic, mineralogical (both qualitative and quantitative), and morphological analysis. This study allows for a careful evaluation of the parameters that influence the formation and properties of Ba5Si8O21:Eu2+,Dy3+ phosphors. As for the synthesis conditions, the use of Na2SiO3, BaCO3 and NH4Cl as precursors was very important to reduce the temperature and time of synthesis. The reducing atmosphere produced with purified coal was cheaper and gave results similar to the more traditional gas mixture (H2/N2). At the end of this study, a phosphor with improved long persistent phosphorescence (LPP) characteristics was obtained with Ba/Si = 0.7, Eu/Si = 2.8 × 10?3 and Dy/Si = 3.6 × 10?3 following a 6 h-synthesis in a quartz crucible.
关键词: barium silicates,kinetic analysis,luminescence,quantitative phase analysis,phosphors
更新于2025-09-23 15:22:29
-
Design and Characterisation of Titanium Nitride Subarrays of Kinetic Inductance Detectors for Passive Terahertz Imaging
摘要: We report on the investigation of titanium nitride (TiN) thin films deposited via atomic layer deposition (ALD) for microwave kinetic inductance detectors (MKID). Using our in-house ALD process, we have grown a sequence of TiN thin films (thickness 15, 30, 60 nm). The films have been characterised in terms of superconducting transition temperature Tc, sheet resistance Rs and microstructure. We have fabricated test resonator structures and characterised them at a temperature of 300 mK. At 350 GHz, we report an optical noise equivalent power NEPopt ≈ 2.3 × 10?15 W/√Hz, which is promising for passive terahertz imaging applications.
关键词: Titanium nitride,ALD,Kinetic inductance detector
更新于2025-09-23 15:22:29