- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Vascular and structural alterations of the choroid evaluated by optical coherence tomography angiography and optical coherence tomography after half-fluence photodynamic therapy in chronic central serous chorioretinopathy
摘要: Purpose To concurrently evaluate the effect of half-fluence photodynamic therapy (hf PDT) on choriocapillaris (CC) perfusion and choroidal structure in chronic central serous chorioretinopathy (CSC). Methods This prospective study included 48 eyes of 41 patients with chronic CSC. Enhanced depth imaging optical coherence tomography and optical coherence tomography angiography (OCTA) images were analyzed. Choroidal area (CA), luminal area (LA), and stromal area (SA) were computed using Image J software. Results One month after hf-PDT, total CA decreased to 1.312 mm2 from 1.490 mm2 (p < 0.001), LA decreased to 0.981 mm2 from 1.097 mm2 (p < 0.001), and SA decreased to 0.331 mm2 from 0.393 mm2 (p < 0.001). In OCTA, the CC flow in the eyes with CSC (17.75 mm2) was statistically significantly lower than the fellow eyes (18.93 mm2) at the baseline visit (p < 0.001). After hf-PDT, the flow in the choriocapillaris statistically significantly increased to 18.81 mm2 at the first month (p = 0.02). Conclusions OCTA proves that after hf-PDT a significant increase in CC perfusion occurred at first month. The decrease of the luminal areas in enhanced depth imaging optical coherence tomography is mainly due to a decrease in large-caliber vessels, which indicates that hf-PDT has an effect on larger choroidal vessels and spares CC flow.
关键词: Chronic central serous chorioretinopathy,Optical coherence tomography angiography,Half-fluence photodynamic therapy,Choriocapillaris perfusion
更新于2025-09-23 15:23:52
-
Absolute quantification (ml blood/sec???mm2 tissue) of normal vs. diabetic foot skin microvascular blood perfusion: Feasibility of FM-PPG measurements under clinical conditions
摘要: Fluorescence-mediated photoplethysmography (FM-PPG) is the first routine clinical methodology by which to quantifiably measure tissue blood perfusion in absolute terms (mL blood/sec ? mm2 tissue). The FM-PPG methodology has been described in detail previously in this journal (MVR 114, 2017, 92-100), along with initial proof-of-concept measurements of blood perfusion in both ocular and forearm skin tissues. The motivation for the current study was to investigate whether FM-PPG can be used readily and routinely under realistic clinical conditions. The vehicle for doing this was to measure medial foot capillary blood flow, i.e., tissue perfusion, in 7 normal subjects, mean = 6.76 ± 2.29 E-005 mL/(sec ? mm2), and lesion-free areas of 8 type-2 diabetic patients with skin ulceration, mean = 4.67 + 3.15 E-005 mL/(sec ? mm2). Thus, perfusion in the diabetics was found to be moderately lower than that in the normal control subjects. Earlier skin perfusion measurements in medial forearms of 4 normal subjects, mean = 2.64 + 0.22 E-005 mL/(sec ? mm2), were lower than both the normal and diabetic foot perfusion measurements. Variability in the heartbeat-to-heartbeat blood perfusion pulses in the skin capillaries, defined as the ratio of the standard deviation among beat-to-beat pulses divided by the mean perfusion of those pulses, was determined for each subject. Average variability in foot skin was 21% in the diabetic population, versus 16% for normal subjects; and it was 18% in forearm skin. We conclude that absolute quantitative FM-PPG measurement of skin blood perfusion at the level of nutritive capillaries is feasible routinely under clinical conditions, allowing for quantitative measurement of skin tissue blood perfusion in absolute terms.
关键词: Indocyanine green dye,Type-2 diabetes,Fluorescence-mediated photoplethysmography,Foot skin blood perfusion,Absolute quantification
更新于2025-09-23 15:23:52
-
Feasibility of simultaneous dual isotope acquisition for myocardial perfusion imaging with a cadmium zinc telluride camera
摘要: Background. We studied the impact of technetium-99m (99mTc) in the thallium-201 (201Tl) energy window (70 keV) to determine if CZT cardiac cameras allow us to perform simultaneous dual-isotope acquisition for myocardial perfusion imaging. Methods. We included 117 consecutive patients. We injected 0.7 MBq/kg of 201Tl at stress, performed the first scan (image T1), then injected at rest 2 MBq/kg of 99mTc-tetrofosmin and immediately acquired a second scan with reconstruction in the energy window of thallium (image T2). A corrected thallium image was created by the subtraction of 99mTc downscattered photons (image TS). We compared spectra, image quality, and semiquantitative scores on T1, T2, and TS images. Results. Though T2 images were of worse quality, TS images were of equal quality compared to T1 images in most cases. Scores show an underestimation of abnormalities in 20% of patients on T2 images and in 10% on TS images. Conclusions. Despite the improved energy resolution of CZT cameras, downscatter of technetium in the 201Tl window leads to an underestimation of the pathological territory in 10% to 20% of cases. It does not allow us to use simultaneous dual-isotope acquisition in clinical practice without additional tools for scatter correction.
关键词: Simultaneous dual-isotope,Myocardial perfusion imaging,Technetium-99m,Thallium-201,CZT camera
更新于2025-09-23 15:23:52
-
Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms
摘要: Objectives To assess the influence of image noise on computed tomography (CT) perfusion studies, CT perfusion software algorithms were evaluated for susceptibility to image noise and results applied to clinical perfusion studies. Methods Digital perfusion phantoms were generated using a published deconvolution model to create time-attenuation curves (TACs) for 16 different combinations of blood flow (BF; 30/60/90/120 ml/100 ml/min) and flow extraction product (FEP; 10/20/30/40 ml/100 ml/min) corresponding to values encountered in clinical studies. TACs were distorted with Gaussian noise at 50 different strengths to approximate image noise, performing 200 repetitions for each noise level. A total of 160,000 TACs were evaluated by measuring BF and FEP with CT perfusion software, comparing results for the maximum slope and Patlak models with those obtained with a deconvolution model. To translate results to clinical practice, data of 23 patients from a CT perfusion study were assessed for image noise, and the accuracy of reported CT perfusion measurements was estimated. Results Perfusion measurements depend on image noise as means and standard deviations of BF and FEP over repetitions increase with increasing image noise, especially for low BF and FEP values. BF measurements derived by deconvolution show larger standard deviations than those performed with the maximum slope model. Image noise in the evaluated CT perfusion study was 26.46 ± 3.52 HU, indicating possible overestimation of BF by up to 85% in a clinical setting. Conclusions Measurements of perfusion parameters depend heavily upon the magnitude of image noise, which has to be taken into account during selection of acquisition parameters and interpretation of results, e.g., as a quantitative imaging biomarker.
关键词: Tomography, x-ray computed,Phantoms, imaging,Perfusion imaging,Software,Artifacts
更新于2025-09-23 15:23:52
-
Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction
摘要: Background. Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. Methods. Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(99mTc-tetrofosmin (TF) or 123I-BMIPP first) followed by simultaneous 99mTc-TF /123I-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. Results. The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for 99mTc-TF: 0.97/ for 123I-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). Conclusion. The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous 99mTc-TF /123I-BMIPP dual-tracer acquisitions in clinical settings.
关键词: acute myocardial infarction,dual imaging,CZT camera,Perfusion-metabolism mismatch
更新于2025-09-23 15:23:52
-
Current Status of Patient Radiation Exposure of Cardiac Positron Emission Tomography and Single-Photon Emission Computed Tomographic Myocardial Perfusion Imaging
摘要: BACKGROUND: Radiation exposure during nuclear cardiology procedures has received much attention and has prompted citations for radiation reduction. In 2010, the American Society of Nuclear Cardiology recommended reducing the average patient study radiation exposure to <9 mSv in 50% of studies by 2014. Cardiac positron emission tomography (PET) for myocardial perfusion imaging (MPI) has emerged within recent years, but current radiation exposure in cardiac nuclear PET laboratories is unknown. This study evaluated current reported patient radiation exposure from nuclear laboratories in the United States applying for Intersocietal Accreditation Commission accreditation for MPI using single photon emission computed tomography (SPECT) or PET. METHODS AND RESULTS: This was an analysis of nuclear cardiology studies submitted to the Intersocietal Accreditation Commission for either or both cardiac PET and SPECT accreditation. Cardiac SPECT data represented year 2015 while PET data combined years 2013 to 2015. Data was analyzed with χ2 and Mann-Whitney U tests (reported as median, 25th percentile, and 75th percentile). Reported PET MPI radiation exposure for 111 laboratories (532 patient cases) was 3.7 (3.2–4.1) mSv per study with no geographic variation. Reported SPECT MPI radiation exposure for 665 laboratories (3067 patient studies) was 12.8 (12.2–14.3) mSv. Highest radiation exposure was found in the South region. Technetium-only studies resulted in a median of 12.2 mSv per study. CONCLUSIONS: Radiation exposure from cardiac PET MPI in US laboratories applying for Intersocietal Accreditation Commission accreditation is low (111 laboratories, 3.7 mSv) and substantially lower than cardiac SPECT (665 laboratories, 12.8 mSv).
关键词: technetium,accreditation,myocardial perfusion imaging,positron emission tomography,radiation exposure
更新于2025-09-23 15:23:52
-
Novel SPECT Technologies and Approaches in Cardiac Imaging
摘要: Recent novel approaches in myocardial perfusion single photon emission CT (SPECT) have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv) stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.
关键词: fast myocardial perfusion single photon emission computed tomography,quantification,single photon emission computed tomography,low dose,myocardial perfusion imaging,stress only
更新于2025-09-23 15:22:29
-
Comparative Study of Optical Coherence Tomography Angiography and Phase-Resolved Doppler Optical Coherence Tomography for Measurement of Retinal Blood Vessels Caliber
摘要: Purpose: To compare the accuracy of Doppler optical coherence tomography (DOCT) and OCT angiography (OCTA) for measuring retinal blood vessel caliber at different flow rates. Methods: A research-grade 1060-nm OCT system with 3.5-lm axial resolution in retinal tissue and 92,000 A scan/s image acquisition rate was used in this study. DOCT and OCTA measurements were acquired both from a flow phantom and in vivo from retinal blood vessels in six male Brown Norway rats. The total retinal blood flow (TRBF) was modified from baseline to 70% and 20% of baseline by reducing the ocular perfusion pressure (OPP). The retinal blood vessel caliber (RBVC) was measured from OCTA and DOCT images. The caliber measurements were conducted by two separate graders using a custom MATLAB-based image processing algorithm. Results: The RBVC measured with OCTA and DOCT for normal blood flow rates were not significantly different (56.69 6 12.17 and 57.17 6 9.46 lm, P ? 0.27, respectively). However, significant differences were detected when TRBF was reduced to 70% (55.69 6 11.56 vs. 50.62 6 8.85 lm, P , 0.01) and 20% (50.29 6 9.29 vs. 44.88 6 7.13 lm, P , 0.01) of baseline. Conclusions: Reduced TRBF resulted in inaccuracy of the RBVC measurements with DOCT in both the phantom and animal study. This result suggests that OCTA is a more accurate tool for RBVC evaluation when applied to retinal diseases associated with reduced TRBF, such as glaucoma and diabetic retinopathy. Translational Relevance: Results from this study are directly applicable to clinical studies of retinal blood flow measured with OCTA and DOCT.
关键词: optical coherence tomography angiography,ocular perfusion pressure,retinal imaging,doppler optical coherence tomography
更新于2025-09-23 15:22:29
-
Indocyanine green-based fluorescence imaging in visceral and hepatobiliary and pancreatic surgery: State of the art and future directions
摘要: In recent years, the use of fluorescence-guided surgery (FGS) to treat benign and malignant visceral, hepatobiliary and pancreatic neoplasms has significantly increased. FGS relies on the fluorescence signal emitted by injected substances (fluorophores) after being illuminated by ad hoc laser sources to help guide the surgical procedure and provide the surgeon with real-time visualization of the fluorescent structures of interest that would be otherwise invisible. This review surveys and discusses the most common and emerging clinical applications of indocyanine green (ICG)-based fluorescence in visceral, hepatobiliary and pancreatic surgery. The analysis, findings, and discussion presented here rely on the authors’ significant experience with this technique in their medical institutions, an up-to-date review of the most relevant articles published on this topic between 2014 and 2018, and lengthy discussions with key opinion leaders in the field during recent conferences and congresses. For each application, the benefits and limitations of this technique, as well as applicable future directions, are described. The imaging of fluorescence emitted by ICG is a simple, fast, relatively inexpensive, and harmless tool with numerous different applications in surgery for both neoplasms and benign pathologies of the visceral and hepatobiliary systems. The ever-increasing availability of visual systems that can utilize this tool will transform some of these applications into the standard of care in the near future. Further studies are needed to evaluate the strengths and weaknesses of each application of ICG-based fluorescence imaging in abdominal surgery.
关键词: visceral perfusion,Peritoneal carcinomatosis,Pancreatic surgery,Indocyanine green,Liver surgery,Gastrointestinal surgery,Biliary surgery,Fluorescence imaging,Biliary anatomy
更新于2025-09-23 15:22:29
-
Intraoperative indocyanine green angiography for the objective measurement of blood flow
摘要: Purpose: Intraoperative assessment of tissue perfusion is important to predict wound healing or improvement of symptoms in patients with peripheral arterial disease (PAD) or vascular trauma. There is no widely accepted standard for intraoperative measurement of tissue perfusion. Here, we report the use of indocyanine green (ICG)-based angiography to determine the blood flow in patients with PAD and vascular trauma. Methods: The SPY fluorescent imaging system was utilized. A dose of 3–5 mL of ICG (2.5 mg/mL) was injected intravenously followed by a 10-mL normal saline flush. The SPY imaging system was used to quantitatively assess perfusion. During the study period, the SPY imaging system was applied in 4 patients with PAD and one patient with vascular trauma. Results: In 3 patients with PAD associated with an ischemic wound, complete wound healing was achieved with the indication of viable tissue by the SPY system. In one patient with severe claudication in both lower extremities, the ICG angiography was used to determine the increased blood flow after revascularization. In the case of vascular trauma, this imaging system enabled the delineation of viability of the injured tissue. Conclusion: ICG angiography can determine the surface tissue viability in PAD patients. In cases of severe vascular trauma, the SPY system can be used to determine tissue perfusion. Further study is warranted to define the definite utility of this technology to assess perfusion, response to revascularization, and potentially, to predict the likelihood of wound healing.
关键词: Peripheral arterial disease,Perfusion,Angiography,Indocyanine green
更新于2025-09-23 15:22:29