- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Development of a new high-speed readout system for SOI pixel detectors
摘要: We are developing a new high-speed readout system for silicon on insulator (SOI) pixel detectors. The SOI detector is a monolithic radiation imaging detector based on a 0.2 μm FD-SOI CMOS process. Previously, we used a Xilinx Virtex-4/5 FPGA readout board for the SOI detector and developed many facilities for this board. However, the Virtex-4/5 FPGA is now obsolete and does not have sufficiently high performance for recent experiments that require more than 1-kHz high-speed imaging with a large number of pixels. Thus, we started to develop a new high-speed readout system using the KC705, which is the evaluation board for the Xilinx Kintex-7 FPGA. We developed a new data acquisition structure that has backward compatibility with the previous environment on this board and implements several functions for practical purposes such as micro Computed Tomography. The transfer speed achieved by the new system is 95.3 fps for a 426k pixel detector in continuous data-taking mode, and 762.5 fps in maximum-speed mode. The details of the new readout system are presented.
关键词: X-ray imaging,SOI,FPGA,DAQ,Pixel detector
更新于2025-09-23 15:23:52
-
Edge-illumination x-ray phase contrast imaging restoration using discrete curvelet regularization transform
摘要: This article considers the problem of recovering edge-illumination x-ray phase contrast (EIXPC) images from a set of potentially Poisson noisy projection measurements. The authors cast a recovery as a sparse regularization problem based on Anscombe multiscale variance stabilizing transform (MS-VST) with fast discrete curvelet transform which was applied to simulated edge-illumination x-ray phase contrast images. For accurate modelling, the noise characteristics of the EIXPCi data are used to determine the relative importance of each projection. Two implementations of curvelet sparse regularization transforms were applied, including the unequally-spaced fast Fourier transform and the wrapping-based transform. The algorithms were evaluated in terms of contrast improvement, quality of image restoration, object perceptibility, and peak signal-to-noise ratio. The methods provide nearly optimal solution without excessive memory and recovery time requirement. The performance of the proposed algorithms is demonstrated through a series of complex numerical geometric and anthropomorphic phantom studies. The results of numerical simulations demonstrate that the discrete curvelet transform with MS-VST is fast and robust, and it can effectively improve image quality, preserve and enhance edges and restore lost information while signi?cantly reducing the noise. Additionally, both sparse sampling and decreasing x-ray tube current (i.e. noisy data) lead to the reduction of radiation dose in the x-ray imaging.
关键词: x-ray imaging,x-ray phase-contrast,curvelet regularization,biomedical imaging
更新于2025-09-23 15:22:29
-
Conformal image-guided microbeam radiation therapy at the ESRF biomedical beamline ID17
摘要: Purpose: Upcoming veterinary trials in microbeam radiation therapy (MRT) demand for more advanced irradiation techniques than in preclinical research with small animals. The treatment of deep-seated tumors in cats and dogs with MRT requires sophisticated irradiation geometries from multiple ports, which impose further efforts to spare the normal tissue surrounding the target. Methods: This work presents the development and benchmarking of a precise patient alignment protocol for MRT at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF). The positioning of the patient prior to irradiation is verified by taking x-ray projection images from different angles. Results: Using four external fiducial markers of 1.7 mm diameter and computed tomography-based treatment planning, a target alignment error of less than 2 mm can be achieved with an angular deviation of less than 2?. Minor improvements on the protocol and the use of smaller markers indicate that even a precision better than 1 mm is technically feasible. Detailed investigations concerning the imaging dose lead to the conclusion that doses for skull radiographs lie in the same range as dose reference levels for human head radiographs. A currently used online dose monitor for MRT has been proven to give reliable results for the imaging beam. Conclusions: The ESRF biomedical beamline ID17 is technically ready to apply conformal image-guided MRT from multiple ports to large animals during future veterinary trials.
关键词: microbeam radiation therapy,image-guidance,x-ray imaging,fiducial markers,synchrotron radiation
更新于2025-09-23 15:22:29
-
Direct quantitative material decomposition employing grating-based X-ray phase-contrast CT
摘要: Dual-energy CT has opened up a new level of quantitative X-ray imaging for many diagnostic applications. The energy dependence of the X-ray attenuation is the key to quantitative material decomposition of the volume under investigation. This material decomposition allows the calculation of virtual native images in contrast enhanced angiography, virtual monoenergetic images for beam-hardening artifact reduction and quantitative material maps, among others. These visualizations have been proven beneficial for various diagnostic questions. Here, we demonstrate a new method of ‘virtual dual-energy CT’ employing grating-based phase-contrast for quantitative material decomposition. Analogue to the measurement at two different energies, the applied phase-contrast measurement approach yields dual information in form of a phase-shift and an attenuation image. Based on these two image channels, all known dual-energy applications can be demonstrated with our technique. While still in a preclinical state, the method features the important advantages of direct access to the electron density via the phase image, simultaneous availability of the conventional attenuation image at the full energy spectrum and therefore inherently registered image channels. The transfer of this signal extraction approach to phase-contrast data multiplies the diagnostic information gained within a single CT acquisition. The method is demonstrated with a phantom consisting of exemplary solid and fluid materials as well as a chicken heart with an iodine filled tube simulating a vessel. For this first demonstration all measurements have been conducted at a compact laser-undulator synchrotron X-ray source with a tunable X-ray energy and a narrow spectral bandwidth, to validate the quantitativeness of the processing approach.
关键词: Dual-energy CT,virtual non-contrast images,grating-based phase-contrast,electron density,effective atomic number,material decomposition,quantitative X-ray imaging,virtual monoenergetic images
更新于2025-09-23 15:21:21
-
Locality estimates for Fresnel-wave-propagation and stability of x-ray phase contrast imaging with finite detectors
摘要: Coherent wave-propagation in the near-field Fresnel-regime is the underlying contrast-mechanism to (propagation-based) x-ray phase contrast imaging (XPCI), an emerging lensless technique that enables 2D- and 3D-imaging of biological soft tissues and other light-element samples down to nanometer-resolutions. Mathematically, propagation is described by the Fresnel-propagator, a convolution with an arbitrarily non-local kernel. As real-world detectors may only capture a finite field-of-view, this non-locality implies that the recorded diffraction-patterns are necessarily incomplete. This raises the question of stability of image-reconstruction from the truncated data—even if the complex-valued wave-field, and not just its modulus, could be measured. Contrary to the latter restriction of the acquisition, known as the phase-problem, the finite-detector-problem has not received much attention in literature. The present work therefore analyzes locality of Fresnel-propagation in order to establish stability of XPCI with finite detectors. Image-reconstruction is shown to be severely ill-posed in this setting—even without a phase-problem. However, quantitative estimates of the leaked wave-field reveal that Lipschitz-stability holds down to a sharp resolution limit that depends on the detector-size and varies within the field-of-view. The smallest resolvable lengthscale is found to be ≈1/–f times the detector’s aspect length, where –f is the Fresnel number associated with the latter scale. The stability results are extended to phaseless imaging in the linear contrast-transfer-function regime.
关键词: resolution,phase contrast,image reconstruction,stability,x-ray imaging,Fresnel propagation
更新于2025-09-23 15:21:21
-
Measurement of the Modulation Transfer Function for a Backscatter Radiography System Used in Nondestructive Examination
摘要: The need for subsurface flaw detection in materials has led to the recent development of a backscatter radiography system. In order to achieve the optimal system design, the modulation transfer function (MTF) must be characterized for the backscatter system. Although several established methods exist for medical imaging systems, these techniques cannot be directly applied to the backscatter system. The goal of this study was to alter the transmission MTF measurement methods using the bar pattern and edge technique so that accurate and reliable results can be obtained for the backscatter system. Test tools were developed in order to carry out these measurements, with the ultimate goal of providing a target for quality assurance testing of the equipment. Although the edge method results were higher than the bar pattern method, the difference in magnitude was less than 0.1. The MTF measurements indicated the importance of target design and positioning in order to achieve accurate results for a backscatter radiography system used in nondescructive examination.
关键词: X-Ray Imaging,Radiography,Compton Imaging
更新于2025-09-23 15:21:01
-
Correlations between thermal history and keyhole porosity in laser powder bed fusion
摘要: Additive manufacturing has the potential to revolutionize the production of metallic components as it yields near net shape parts with complex geometries and minimizes waste. At the present day, additively manufactured components face qualification and certification challenges due to the difficulty in controlling defects. This has driven a significant research effort aimed at better understanding and improving processing controls – yielding a plethora of in-situ measurements aimed at correlating defects with material quality metrics of interest. In this work, we develop machine-learning methods to learn correlations between thermal history and subsurface porosity for a variety of print conditions in laser powder bed fusion. Un-normalized surface temperatures (in the form of black-body radiances) are obtained using high-speed infrared imaging and porosity formation is observed in the sample cross-section through synchrotron x-ray imaging. To demonstrate the predictive power of these features, we present four statistical machine-learning models that correlate temperature histories to subsurface porosity formation in laser fused Ti-6Al-4V powder.
关键词: in-situ measurement,keyhole porosity,machine learning,laser powder bed fusion,x-ray imaging
更新于2025-09-23 15:21:01
-
Direct observation of pore formation mechanisms during LPBF additive manufacturing process and high energy density laser welding
摘要: Laser powder bed fusion (LPBF) is a 3D printing technology that can print parts with complex geometries that are unachievable by conventional manufacturing technologies. However, pores formed during the printing process impair the mechanical performance of the printed parts, severely hindering their widespread application. Here, we report six pore formation mechanisms that were observed during the LPBF process. Our results reconfirm three pore formation mechanisms - keyhole induced pores, pore formation from feedstock powder and pore formation along the melting boundary during laser melting from vaporization of a volatile substance or an expansion of a tiny trapped gas. We also observe three new pore formation mechanisms: (1) pore trapped by surface fluctuation, (2) pore formation due to depression zone fluctuation when the depression zone is shallow and (3) pore formation from a crack. The results presented here provide direct evidence and insight into pore formation mechanisms during the LPBF process, which may guide the development of pore elimination/mitigation approaches. Since certain laser processing conditions studied here are similar to the situations in high energy density laser welding, the results presented here also have implications for laser welding.
关键词: Pore formation,Laser powder bed fusion,X-ray imaging,Laser welding,Additive manufacturing
更新于2025-09-23 15:21:01
-
25 Gb/s Directly Modulated Widely Tunable 1.3 ??m Dual Wavelength DFB Laser for THz Communication
摘要: This paper presents a readout integrated circuit called UFXC32k, designed for hybrid pixel semiconductor detectors used in X-ray imaging applications. The UFXC32k integrated circuit, designed in a CMOS 130 nm process, contains about 50 million transistors in the area of 9.64 mm × 20.15 mm. The core of the IC is a matrix of 128 × 256 square-shaped pixels of 75 μm pitch. Each pixel contains a charge sensitive ampli?er, a shaper, two discriminators, and two 14-bit ripple counters. The analog front-end electronics allow processing of sensor signals of both polarities (holes and electrons). The UFXC32k chip is bump-bonded to a pixel silicon sensor and is fully characterized using X-ray radiation. The measured equivalent noise charge for the standard settings is equal to 123 e? rms (for the peaking time of 40 ns) and each pixel dissipates 26 μW. Thanks to the use of trim blocks working in each pixel independently, an effective off- set spread calculated to the input is only 9 e? rms with a gain spread of 2%. The maximum count rate per pixel depends mainly on effective CSA feedback resistance. Dead time in the front end can be set as low as 85 ns. In the continuous readout mode, a user can select the number of bits read out from each pixel to optimize the UFXC32k frame rate, e.g., for a readout of 2 bits/pixel with 200 MHz clock, the frame rate is equal to 23 kHz.
关键词: X-ray imaging,pixel detectors,Matching,single photon counting
更新于2025-09-23 15:19:57
-
Vectorial nature in nonlinear multimode interference based ultrafast fiber lasers
摘要: This paper presents a readout integrated circuit called UFXC32k, designed for hybrid pixel semiconductor detectors used in X-ray imaging applications. The UFXC32k integrated circuit, designed in a CMOS 130 nm process, contains about 50 million transistors in the area of 9.64 mm × 20.15 mm. The core of the IC is a matrix of 128 × 256 square-shaped pixels of 75 μm pitch. Each pixel contains a charge sensitive ampli?er, a shaper, two discriminators, and two 14-bit ripple counters. The analog front-end electronics allow processing of sensor signals of both polarities (holes and electrons). The UFXC32k chip is bump-bonded to a pixel silicon sensor and is fully characterized using X-ray radiation. The measured equivalent noise charge for the standard settings is equal to 123 e? rms (for the peaking time of 40 ns) and each pixel dissipates 26 μW. Thanks to the use of trim blocks working in each pixel independently, an effective off-set spread calculated to the input is only 9 e? rms with a gain spread of 2%. The maximum count rate per pixel depends mainly on effective CSA feedback resistance. Dead time in the front end can be set as low as 85 ns. In the continuous readout mode, a user can select the number of bits read out from each pixel to optimize the UFXC32k frame rate, e.g., for a readout of 2 bits/pixel with 200 MHz clock, the frame rate is equal to 23 kHz.
关键词: single photon counting,pixel detectors,Matching,X-ray imaging
更新于2025-09-23 15:19:57