研究目的
Investigating the generation of broadly tunable mid-IR radiation across 12.65 – 15 μm based on the DFG approach using an OP-GaAs crystal.
研究成果
The study successfully demonstrated the generation of broadly tunable mid-IR radiation across 12.65 – 15 μm using DFG in an OP-GaAs crystal, enabling high-resolution spectroscopic investigations of molecular fingerprints in this wavelength range.
研究不足
The output power of the idler laser is relatively low, with the highest achieved power being about 55 μW.
1:Experimental Design and Method Selection:
The experiment utilized difference-frequency generation (DFG) in an orientation-patterned (OP) GaAs crystal to generate tunable mid-IR radiation.
2:Sample Selection and Data Sources:
An external-cavity quantum cascade laser (EC-QCL) and a tunable CO2 laser were used as pump and signal sources, respectively.
3:List of Experimental Equipment and Materials:
Equipment included an EC-QCL, optical isolator, CO2 laser, concave mirrors, beam combiner, parabolic mirrors, liquid-nitrogen-cooled HgCdTe detector, KBr lens, and longpass filter.
4:Experimental Procedures and Operational Workflow:
The pump and signal lasers were aligned and focused onto the OP-GaAs crystal, with the generated idler signal collected and analyzed.
5:Data Analysis Methods:
The output power of the idler laser was measured at different signal wavelengths.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
external-cavity quantum cascade laser
EC-QCL
Used as the pump source for the DFG experimental setup.
-
optical isolator
OI
Used after the EC-QCL to prevent back reflections.
-
CO2 laser
Used as the signal source in the DFG experimental setup.
-
concave mirrors
CMs
Used to optimize the beam waists of the pump and signal lasers inside the crystal for maximum DFG efficiency.
-
beam combiner
BC
Used to align both the pump and signal laser beams.
-
parabolic mirror
PM
Used to focus the aligned pump and signal laser beams onto the OP-GaAs crystal and to collect the idler signal after the crystal.
-
liquid-nitrogen-cooled HgCdTe detector
Used to detect the idler signal.
-
KBr lens
L
Used to focus the idler signal onto the detector.
-
longpass filter
LF
Used to eliminate both the pump and signal lasers before the focusing lens.
-