研究目的
To investigate the biodistribution and in vivo toxicity of InP/ZnS QDs with different surface modifications in BALB/c mice.
研究成果
Surface modification and exposure dose influence the biological behavior and in vivo toxicity of QDs. The surface chemistry should be fully considered in the design of InP-based QDs for biomedical applications.
研究不足
The study focused on short-term effects (28 days) and did not explore long-term toxicity or mechanisms of QDs degradation and excretion.
1:Experimental Design and Method Selection:
Three kinds of InP/ZnS QDs with different surface modifications (hQDs, aQDs, cQDs) were intravenously injected into BALB/c mice at dosages of 2.5 mg/kg BW or 25 mg/kg BW. Biodistribution was determined through cryosection fluorescence microscopy and ICP-MS analysis. Effects on histopathology, hematology, and blood biochemistry were evaluated at 1, 3, 7, 14, and 28 days post-injection.
2:5 mg/kg BW or 25 mg/kg BW. Biodistribution was determined through cryosection fluorescence microscopy and ICP-MS analysis. Effects on histopathology, hematology, and blood biochemistry were evaluated at 1, 3, 7, 14, and 28 days post-injection. Sample Selection and Data Sources:
2. Sample Selection and Data Sources: Healthy female BALB/c mice (6 weeks old) were used. Blood and organ samples were collected at specified time points.
3:List of Experimental Equipment and Materials:
Transmission electron microscopy (TEM), zeta potential and particle size analyzer, fluorescence spectrophotometer, UV/Vis spectrophotometer, ICP-MS, cryosection fluorescence microscopy equipment, automatic blood biochemical analyzer.
4:Experimental Procedures and Operational Workflow:
QDs were characterized before injection. Mice were observed for behavior, weight, and organ index changes. Blood and organ samples were collected and analyzed for QDs distribution and toxicity.
5:Data Analysis Methods:
Statistical analysis was performed using SPSS 22.0. Data were expressed as mean ± standard deviation (SD). Differences among groups were compared by one-way ANOVA.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Transmission electron microscopy
HT7700
HITACHI
Characterization of the shape, size and morphology of QDs
-
Fluorescence spectrophotometer
F-4600
HITACHI
Measurement of fluorescence spectra of QDs
-
Zeta potential and particle size analyzer
Brookhaven Instruments Inc.
Characterization of zeta potential and hydrodynamic size distribution of QDs
-
UV/Vis spectrophotometer
DU720
Beckman Coulter Inc.
Measurement of absorption spectra of QDs
-
ICP-MS
PerkinElmer
Quantitative measurement of In concentration in QDs solution and tissues
-
Automatic blood biochemical analyzer
BS-220
Mindray medical international limited
Detection of serum biochemical parameters
-
Fully automatic five-classification hematology analyzer
BC5310
Mindray medical international limited
Routine blood analysis
-