研究目的
To propose two enhanced EBAC analysis methods, based on the DFT and EBAC integrated system, for the defect isolations with grounded connections in semiconductor industries.
研究成果
The DFT and EBAC integrated system accurately positions failure points, facilitating subsequent PFA and circuit debugs. The two proposed methods enhance EBAC signals for grounded CUTs, successfully demonstrated in real FA cases. This integrated system contributes significantly to semiconductor industries by improving design capability, shortening test time, and effectively capturing manufacturing defects.
研究不足
The traditional EBAC technique fails to identify defects on a grounded CUT due to poor EBAC images. The proposed methods require specific conditions such as the selection of adjacent grounded circuits or sufficient space for circuit isolation.
1:Experimental Design and Method Selection:
The study integrates DFT and EBAC techniques to enhance defect isolation in semiconductor circuits with grounding paths. Two methods are proposed to improve EBAC signal quality for grounded circuits under test (CUTs).
2:Sample Selection and Data Sources:
Real failure analysis (FA) cases from semiconductor manufacturing are used to demonstrate the applicability of the proposed methods.
3:List of Experimental Equipment and Materials:
Scanning electron microscope (SEM), nano-probe, and focused ion beam (FIB) for sample preparation and analysis.
4:Experimental Procedures and Operational Workflow:
Method-1 involves creating a new circuit loop with an adjacent ground line to retain absorbed current for clear EBAC imaging. Method-2 involves isolating the CUT from its grounded line to enhance EBAC signals.
5:Data Analysis Methods:
EBAC images are analyzed to locate defects, with physical FA (PFA) techniques used to confirm defect locations.