研究目的
To investigate the correlation between longitudinal changes in standard automated perimetry (SAP) indices and circumpapillary retinal nerve fiber layer thickness (cpRNFLT) measured using Spectralis OCT with an eye-tracking system (follow-up mode), and to evaluate the impact of introducing a structure-function relationship map and a nonlinear relationship between SAP and OCT results on this correlation.
研究成果
The study supports the practical use of OCT in evaluating glaucoma progression, emphasizing the importance of focusing on corresponding sectorial changes and considering disease severity. The introduction of a structure-function relationship map and a nonlinear relationship between SAP and OCT results improved the correlation between structural and functional changes in glaucoma.
研究不足
1. Small sample size of both cases and experiments. 2. Exclusion of cases with epiretinal membrane or retinoschisis. 3. Modeling did not account for the floor effect in cpRNFLT measurements.
1:Experimental Design and Method Selection:
A prospective longitudinal study was conducted to evaluate the correlation between structural and functional changes in glaucoma using Spectralis OCT with follow-up mode and SAP.
2:Sample Selection and Data Sources:
230 glaucoma patients were enrolled, with 131 eyes of 100 patients meeting the inclusion criteria after exclusions.
3:List of Experimental Equipment and Materials:
Spectralis HRA + OCT system (Heidelberg Engineering, Heidelberg, Germany) and Humphrey Visual Field Analyzer (Carl Zeiss-Meditec, Dublin, CA, USA).
4:Experimental Procedures and Operational Workflow:
Patients underwent comprehensive ophthalmic examinations, including IOP measurement, visual acuity testing, slit-lamp examination, gonioscopy, stereoscopic optic disc photography, SAP, and OCT examinations. Only reliable VF tests and OCT measurements taken in follow-up mode were used.
5:Data Analysis Methods:
Linear mixed models were used to evaluate longitudinal time trends, and best linear unbiased predictors (BLUPs) were calculated to assess individual heterogeneity. Correlation coefficients were calculated to evaluate relationships between VF and OCT cpRNFL in longitudinal changes.