研究目的
To propose and fabricate a novel dual Fabry–Pérot interferometric carbon monoxide gas sensor based on polyaniline/Co3O4 sensing film coated on the optical fibre end face for sensitive detection of trace carbon monoxide gas.
研究成果
The dual F-P interferometric CO sensor based on PANI/Co3O4-coated fibre tip demonstrates high sensitivity (21.61 pm/ppm), excellent linear response, and high selectivity for CO within the range of 0–70 ppm. The sensor's advantages include easy fabrication, high selectivity, and low cost, making it suitable for sensitive detection of toxic CO gas monitoring.
研究不足
The sensor's performance is limited to the detection range of 0–70 ppm of CO gas. The response and recovery times, while acceptable, may not be suitable for all applications requiring faster detection.
1:Experimental Design and Method Selection:
The sensor is designed using a dual Fabry–Pérot interferometer structure composed of standard single-mode-fibre (SMF), endlessly photonic crystal fibre (EPCF), and PANI/Co3O4 sensing membrane (PCSM). The interference spectra are analyzed to detect carbon monoxide concentration.
2:Sample Selection and Data Sources:
The sensor's response to different concentrations of CO gas (0–70 ppm) is recorded in air at room temperature.
3:List of Experimental Equipment and Materials:
Includes SMF, EPCF, PANI/Co3O4 membrane, ASE broadband light source, circulator, optical spectrum analyzer (OSA), and gas chamber.
4:Experimental Procedures and Operational Workflow:
The EPCF is fused with SMF to form the first F-P cavity, and the EPCF end is coated with PANI/Co3O4 to form the second F-P cavity. The sensor's response to CO gas is measured using an OSA.
5:Data Analysis Methods:
The shift in interference spectra is analyzed to determine CO concentration, with sensitivity and selectivity evaluated.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Fusion Splicer
S178C
Furukawa
Used for splicing the standard SMF and EPCF.
暂无现货
预约到货通知
-
Optical Spectrum Analyzer
AQ6370D
Yokogawa
Used to measure the transmission spectra of the sensor.
-
Endlessly Photonic Crystal Fibre
SM-10 PCF
Yangtze Optical Fibre and Cable Joint Stock Limited Company (YOFC)
Forms part of the dual Fabry–Pérot interferometer structure for CO gas sensing.
暂无现货
预约到货通知
-
Single-Mode-Fibre
SMF-28
Forms part of the dual Fabry–Pérot interferometer structure for CO gas sensing.
暂无现货
预约到货通知
-
Circulator
PIOC315P210-type
Jilian Technology Co. Ltd., China
Part of the gas test system for launching light into the sensor.
暂无现货
预约到货通知
-
登录查看剩余3件设备及参数对照表