研究目的
To develop a sensitive and selective near-infrared fluorescent probe for the detection and imaging of endogenous peroxynitrite in biological systems.
研究成果
The probe Cy-SN enables sensitive and selective detection of peroxynitrite with a low detection limit of 26 nM, visible color change, and successful application in imaging exogenous and endogenous peroxynitrite in living cells, demonstrating potential for biological analysis and disease research.
研究不足
The probe's response is pH-dependent, with optimal performance in neutral or alkaline conditions, which may limit applications in acidic environments. The study primarily used cell cultures and serum samples, and further in vivo validation may be needed.
1:Experimental Design and Method Selection:
The study involved designing and synthesizing a benzothiazole-derived cyanine probe (Cy-SN) for specific reaction with peroxynitrite (ONOO-) through oxidative cleavage of conjugated C=C double bonds, leading to fluorescence quenching and color change. Methods included UV-Vis absorption spectroscopy, fluorescence spectroscopy, mass spectrometry, and confocal microscopy for imaging.
2:Sample Selection and Data Sources:
Peroxynitrite was generated from H2O2 and NaNO2; other reactive species were prepared from commercial supplies. Murine RAW264.7 macrophage cells were used for cytotoxicity tests and imaging studies.
3:7 macrophage cells were used for cytotoxicity tests and imaging studies. List of Experimental Equipment and Materials:
3. List of Experimental Equipment and Materials: Equipment included Pekin-Elmer LS-55 luminescence spectrophotometer, Shimadzu UV-2550 spectrometer, Varian Mercury-400 NMR spectrometer, Agilent Technologies 6224 TOF LC/MS mass spectrometer, pHS-3C pH meter, laser Confocal Microscopy (OBSERVER Z1, ZEISS), and Canon 350D digital camera. Materials included various chemicals from Aladdin, Sigma Aldrich, and Sinopharm Chemical Reagent Co. Ltd.
4:Experimental Procedures and Operational Workflow:
Synthesis of Cy-SN probe, preparation of ONOO- and other species, cytotoxicity testing via MTT assay, fluorescence and absorption measurements, mass spectrometry analysis, and confocal imaging of cells treated with probes and ONOO- donors or stimulants.
5:Data Analysis Methods:
Fluorescence intensity changes were analyzed for linear relationships and detection limits. Mass spectrometry data confirmed reaction products. Statistical analysis included standard deviations from triplicate measurements.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
luminescence spectrophotometer
LS-55
Pekin-Elmer
Used for fluorescence spectra measurements.
-
spectrometer
UV-2550
Shimadzu
Used for absorption spectra measurements.
-
mass spectrometer
6224 TOF LC/MS
Agilent Technologies
Used for mass spectra in ESI positive mode.
-
confocal microscope
OBSERVER Z1
ZEISS
Used for confocal fluorescence imaging of cells.
-
digital camera
350D
Canon
Used for taking photographs.
-
NMR spectrometer
Mercury-400
Varian
Used for 1H NMR spectra measurements.
-
pH meter
pHS-3C
Not specified
Used for pH measurements.
-
water purification system
Not specified
Millipore
Used to prepare ultrapure water.
-
登录查看剩余6件设备及参数对照表