研究目的
To test the potential of Raman microspectroscopy to determine carotenoid pigments in snow algae and compare it with HPLC, focusing on different species and life-cycle stages.
研究成果
Raman microspectroscopy is effective for fast, non-invasive detection of carotenoids in snow algae, showing shifts in band positions consistent with pigment ratios. However, it has limitations in precisely discriminating between similar carotenoids, whereas HPLC provides detailed pigment composition but requires extraction. The study highlights the potential of Raman spectroscopy for in situ analysis in extreme environments, such as Mars missions.
研究不足
The ability of Raman spectroscopy to discriminate between structurally similar carotenoid pigments or mixtures in unknown biological systems is limited. The method may not unambiguously identify individual carotenoids due to overlapping signals and environmental interactions.
1:Experimental Design and Method Selection:
The study used Raman microspectroscopy and HPLC for pigment analysis in snow algae samples. Raman spectroscopy was chosen for its non-invasive capabilities and resonance enhancement effects, while HPLC served as a reference method for precise pigment identification.
2:Sample Selection and Data Sources:
Eleven field samples of snow algae were collected from various locations in Europe (Krkono?e Mountains, ?tzal Alps, High Tatras) between 2002 and
3:Samples included different species and life-cycle stages, identified using light microscopy. List of Experimental Equipment and Materials:
20 Equipment included an Olympus BX43 light microscope, Renishaw In Via Reflex Raman spectrometer with a
4:5 nm Ar laser, Waters HPLC system with a Zorbax SB-C18 column, Eppendorf miniSpin plus centrifuge, solvents (methanol, acetone, DMSO, acetonitrile, ethyl acetate, ammonium acetate), and software (QuickPHOTO Camera 0, GRAMS AI, MatLab). Experimental Procedures and Operational Workflow:
5 Samples were centrifuged, pigments extracted using solvent mixtures, and analyzed by HPLC with a ternary gradient elution. Raman analysis involved focusing on single cells with a 50x objective, accumulating 10 scans of 10 s each, and calibrating with benzonitrile. Data were processed for baseline correction and peak fitting.
5:Data Analysis Methods:
HPLC data were analyzed using custom MatLab scripts for pigment quantification. Raman spectra were processed with GRAMS AI software for peak deconvolution using Gaussian/Lorentzian fits and the Levenberg-Marquardt algorithm, evaluated with χ2 parameters.