研究目的
To develop a high-performance photocatalytic fuel cell based on plasmonic silver modified Cr-BiOCl nanosheets for simultaneous electricity production and pollutant removal under visible light irradiation.
研究成果
The Cr-BOC/Ag photocatalyst significantly enhances visible light absorption, charge carrier generation, and transfer due to Cr doping and Ag LSPR effects, leading to improved photocatalytic activity and PFC performance. Optimal conditions yield high removal efficiencies and Coulombic efficiencies, demonstrating potential for environmental and energy applications. Future work should focus on further optimizing parameters and exploring real-world implementations.
研究不足
The study is limited to specific pollutants (RhB, MO, TC) and conditions (pH, temperature variations tested but not exhaustive). The scalability and long-term stability in real-world applications are not fully addressed. The use of noble metal Ag may increase cost, and the synthesis methods might require optimization for industrial-scale production.
1:Experimental Design and Method Selection:
The study involved synthesizing Cr-doped BiOCl (Cr-BOC) via a hydrothermal method and Ag-modified Cr-BOC (Cr-BOC/Ag) via photoreduction. Photocatalytic activity was evaluated using RhB, MO, and TC degradation under visible light. A PFC system was constructed with Cr-BOC/Ag as photoanode, Pt as cathode, and Ag/AgCl as reference electrode.
2:Sample Selection and Data Sources:
Samples included pure BiOCl, Cr-BOC with varying Cr doping (mass ratios from experimental dosages), and Cr-BOC/Ag with varying Ag loading (mass ratios from AgNO3 dosages). Pollutants used were RhB, MO, and TC in aqueous solutions.
3:List of Experimental Equipment and Materials:
Equipment included Rigaku D/max 2500 X-ray diffractometer, FE-SEM Hitachi S-4800, TEM Tecnai G2 F20, XPS ESCALAB 250, UV-vis spectrophotometer Hitachi U-4100, ESR Brucker A300, FluoroMax-4 Spectrofluorometer, CHI660E workstation, 300 W Xe lamp with cutoff filter, total carbon analyzer Shimadzu. Materials included Bi(NO3)3·5H2O, NaCl, Mannitol, PVP-30K, CrCl3·6H2O, AgNO3, Ethanol, RhB, MO, TC, Na2SO4 from Sinopharm Chemical Reagent Co.
4:Experimental Procedures and Operational Workflow:
Synthesis of Cr-BOC involved hydrothermal reaction at 160°C for 3h. Synthesis of Cr-BOC/Ag involved photoreduction under visible light for 1h. Characterization included XRD, SEM, TEM, XPS, DRS, ESR, PL, 3D EEMs. Photocatalytic tests involved dispersing catalysts in pollutant solutions, stirring in dark for 30min, irradiating with visible light, sampling at intervals, and measuring concentrations. PFC measurements used a three-electrode system with FTO substrates, supporting electrolyte Na2SO4, and various fuels.
5:3h. Synthesis of Cr-BOC/Ag involved photoreduction under visible light for 1h. Characterization included XRD, SEM, TEM, XPS, DRS, ESR, PL, 3D EEMs. Photocatalytic tests involved dispersing catalysts in pollutant solutions, stirring in dark for 30min, irradiating with visible light, sampling at intervals, and measuring concentrations. PFC measurements used a three-electrode system with FTO substrates, supporting electrolyte Na2SO4, and various fuels. Data Analysis Methods:
5. Data Analysis Methods: Data analyzed using UV-vis spectrophotometry for concentration measurements, electrochemical techniques for photocurrent, EIS, J-V curves, and IPCE. Statistical analysis included standard deviations from triplicate experiments. TOC analysis for mineralization efficiency, and Coulombic efficiency calculated from integrated current and COD changes.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
X-ray diffractometer
Rigaku D/max 2500
Rigaku
Characterization of crystal structure via XRD patterns
暂无现货
预约到货通知
-
Field emission scanning electron microscope
FE-SEM Hitachi S-4800
Hitachi
Investigation of architectural features and morphology
暂无现货
预约到货通知
-
UV-vis spectrophotometer
Hitachi U-4100
Hitachi
Measurement of diffuse reflectance UV-vis absorption spectra
暂无现货
预约到货通知
-
Electron spin resonance spectrometer
Brucker A300
Brucker
Recording ESR signals for detection of radicals and defects
暂无现货
预约到货通知
-
Spectrofluorometer
FluoroMax-4
HORIBA
Collection of photoluminescence spectra and 3D EEMs
暂无现货
预约到货通知
-
Electrochemical workstation
CHI660E
CH Instruments
Measurement of photocurrent responses, EIS, J-V curves, and other electrochemical properties
暂无现货
预约到货通知
-
Total carbon analyzer
Shimadzu
Shimadzu
Detection of total organic carbon concentration for mineralization assessment
暂无现货
预约到货通知
-
Transmission electron microscope
Tecnai G2 F20
Tecnai
Obtaining TEM and HRTEM images for structural analysis
-
X-ray photoelectron spectroscope
ESCALAB 250
ESCALAB
Analysis of surface chemical composition and binding states
暂无现货
预约到货通知
-
Xe lamp
CEL-HXF300
CEL
Providing visible light irradiation for photocatalytic experiments
暂无现货
预约到货通知
-
Irradiatometer
PL-MW2000
PL
Detection of light intensity of incident light
暂无现货
预约到货通知
-
登录查看剩余9件设备及参数对照表